An annual range service is required by most insurance companies to comply with their policy and it is essential for maintaining safe and reliable equipment. Here at Hopkins we complete a full service after which you will receive a service certificate. Our range engineers are COMCAT 4 qualified with years of experience in the industry.

 

Book your Range Service 

If you have a Hopkins frying range and you are in need of a service don’t delay and call us today!



Our traditional range service guidelines include the following:

  • Perform a gas tightness test on fish range internal pipe work.
  • Strip down equipment, remove stainless steel top work(if possible) to the base frame.
  • Remove pans.
  • Visually check welds.
  • Re-seat pans on new fire cement.
  • Remove down ducts to gain access to stream duct.
  • Clean out and empty sump box.
  • Clean extractor fan and impeller blade.
  • Cut in inspection doors where possible and clean ducting via these points (up to the extractor).
  • Check flue using a Smoke pull test on completion.
  • Check thermostats and high limit stats are working.
  • Check out electrical wiring and replace any faulty component.
  • Re-assemble range, fill with oil/fat and test up to temp on all pans.
  • On open flue appliances a spillage test must be performed on completion of service.

Our high efficiency range service guidelines include the following:

  • Ensure that the Gas and Electric are switched off and the pans are empty.
  • Remove front panels if a counter or island range.
  • Remove fish rack cover.
  • Disconnect and remove the lighting gantry, check wiring and fittings.
  • Remove sliding glass doors, remove fish racks.
  • Disconnect and check wires and fittings of the chip box heaters.
  • Remove apron.
  • Remove the capillary guard, high limit thermostat probes and filters from each pan.
  • Disconnect the temperature probes from the computers.
  • Disconnect the burner plaque.
  • Remove the extraction outlets from the back of each pan.
  • Check the burner gasket and replace where necessary (replace every 12 months).
  • Check and clean steam and gas condensers.
  • Check all wiring and controls on the range frame.
  • Dismantle and clean the extractor.
  • Dismantle, check and clean the sump box and all other ducting.
  • Rebuild extraction system.
  • Replace ignition leads, probes and gaskets where applicable.
  • Refit the pan and blower system, replace burner gaskets.
  • Replace the air filter on each burner system.
  • Pressure test the gas system.
  • Rebuild the whole range, reconnecting all thermostats, lights and heaters.
  • Test gas settings on each pan with an appropriate flue gas analyser.
  • Finally test all controls systems, thermostat and high-limit circuits.
  • Test the high-limit thermostat by setting the display off-set to -40 (see control adjustments) and the set temperature to 190 allow the frying media to an actual temperature of 225’c (+/- 10’c) and ensure that the high-limit thermostat trips. When completed REMEMBER to adjust the off-set back to its original setting. Extreme caution is required during this operation. 